Are the cut charts the same for the pac 182 and 186 ? We have 2 manuals for the HD 1070 rev. 0 and rev 10 .Rev. 10 uses the 182 charts. Thanks

specter
12-13-2010, 08:41 AM
I noticed this was never answered. So either RRI found the answer or figured it out.

jimcolt
12-13-2010, 08:11 PM
They use essentially the same cut charts. The early PAC182 charts were for cutting to 70 Amps, the 186 had 100 amp capability. Through 70 Amps they are identical.

These torch numbers refer to the torches used with the Hypertherm HD1070 and HD3070 HyDefinition systems from the 1990's. There are a few still out there running....but they have been replaced with the HPR130, HPR260, HPR400 and HPR800 systems.