Coleman Powermate portable Generator

ok the motor is kawasaki gas engine it starts and runs, but no electric output to the 120v plugs this is an older generator and has sat for a while,::: any input on this would be helpfull
__________________
Yancey (Boomer Trash)

BoilerMaker
IBB Local 374
Hammond, Indiana

AT THE HALL WAITIN FOR A CALL
Reply With Quote
  #2  
Old 09-22-2010, 12:30 PM
papaof2 papaof2 is offline
WeldingWeb Journeyman
 
Join Date: Jul 2010
Location: Georgia, USA
Posts: 150
Re: Coleman Powermate portable Generator

If the generator is NOT an inverter-based unit, it probably needs to be flashed. The metal core of the generator can lose its magnetic field over time and then can't produce electricity.
Without a manaul for your generator, I can't give you a guaranteed procedure, but you might try connecting 12 volts DC to the AC output receptacle of the generator while it's off The term "flash" means just that - you only need to brush the wire across a battery terminal long enough to see the spark.

No guarantees - some generators require partial disassembly to get to the correct terminals for flashing.

John

Last edited by papaof2; 09-22-2010 at 12:31 PM. Reason: spelling
Reply With Quote
  #3  
Old 09-22-2010, 01:03 PM
Broccoli1's Avatar
Broccoli1 Broccoli1 is offline
Master Welder
 
Join Date: Dec 2007
Location: Los Angeles
Posts: 4,635
Re: Coleman Powermate portable Generator

here is a link for Flashing the genset

http://www.alpharubicon.com/altenergy/colemanpenwu.htm
__________________
Ed Conley
http://www.screamingbroccoli.net/
MM252
MM211
Passport Plus & Spool gun
TA 185
Lincoln SP135 Plus- (Gone to a good home)
Miller 125c Plasma 120v
O/A set
SO 2020 bender
Beer in the fridge
Reply With Quote
  #4  
Old 09-22-2010, 04:59 PM
NTLBM's Avatar
NTLBM NTLBM is offline
WeldingWeb Apprentice
 
Join Date: Sep 2010
Location: IN,USA
Posts: 10
Re: Coleman Powermate portable Generator

was unable to find auser manual anywhere they do not exist anymore, found out it is brushless does not have brushes I tried to flash the jenset by useing a double male plug from generator to a 115 house plug however that did turn on the droplight I had pluged into the generator while it was backflowed but did not repolarize it ,,,,, So i believe it hat bad Diods or Rotor damage thanks for all the feedback
__________________
Yancey (Boomer Trash)

BoilerMaker
IBB Local 374
Hammond, Indiana

AT THE HALL WAITIN FOR A CALL
Reply With Quote
Reply

Thread Tools
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is Off
HTML code is Off

Forum Jump


All times are GMT -4. The time now is 05:25 AM.


Powered by vBulletin® Version 3.8.7
Copyright ©2000 - 2013, vBulletin Solutions, Inc.
Copyright ©2000 - 2013, Penton Media, Inc. All rights reserved.