Topic Review (Newest First)

  • 05-03-2021
    CAVEMANN

    Re: Can I use #1 AWG welding cable for Dialarc HF ?

    I like to add a 6 or 8 foot whip at the stinger to keep weight down, it allows you to add more lead too if the need arises.
  • 05-02-2021
    M J D

    Re: Can I use #1 AWG welding cable for Dialarc HF ?

    Quote Originally Posted by leightrepairs View Post
    LC-40 rated is rated at 350 amps, just not made for #1 wire but a copper shim will fix that easily enough.
    That makes more sense. Other than a whip lead I've always been around 0 or 00 cable.
  • 05-02-2021
    leightrepairs

    Re: Can I use #1 AWG welding cable for Dialarc HF ?

    LC-40 rated is rated at 350 amps, just not made for #1 wire but a copper shim will fix that easily enough.
  • 05-02-2021
    M J D

    Re: Can I use #1 AWG welding cable for Dialarc HF ?

    Quote Originally Posted by Jonath108 View Post
    The connectors for the machine as well as for the leads call for 1/0 as a minimum wire size.
    I was told that #1 awg was fine for 300 or 310 ( max on dial arc ) for a total of 50’ leads.
    The connectors that have #1 as a minimum size only go up to 250 amps.
    I like to have the ability to max out my amps at 310 if needed, therefore I will need the connectors good for 350.
    There are no connectors I see that are good to 300 amps.
    Thanks
    I didn't know they were rated that low. I've seen and used lc-40 connectors at around 400 amps with no issues.
  • 05-02-2021
    Jonath108

    Re: Can I use #1 AWG welding cable for Dialarc HF ?

    Quote Originally Posted by Jonath108 View Post
    Thank you, Stickman ! Lenco should be fine.
    The connectors for the machine as well as for the leads call for 1/0 as a minimum wire size.
    I was told that #1 awg was fine for 300 or 310 ( max on dial arc ) for a total of 50’ leads.
    The connectors that have #1 as a minimum size only go up to 250 amps.
    I like to have the ability to max out my amps at 310 if needed, therefore I will need the connectors good for 350.
    There are no connectors I see that are good to 300 amps.
    Thanks
  • 05-02-2021
    frieed

    Re: Can I use #1 AWG welding cable for Dialarc HF ?

    I put a pair of 50' #2 leads (100' total) on my Idealarc 250 with no issues (though I don't go over 1/8" 7018)
    So from the chart above I could have gone to 150' with 60% duty cycle @200A and still use #2
    I bought Southwire Royal Excelene brand from a major wire and cable supplier via their ebay site.
    Really nice flexible stuff.
  • 05-02-2021
    Jonath108

    Re: Can I use #1 AWG welding cable for Dialarc HF ?

    Quote Originally Posted by Stick-man View Post
    If you want quick connectors, look at the following. These are compatible with the popular 2-MPC Tweco connectors. I prefer Lenco brand for price and quality.

    https://profax-lenco.com/wp-content/...Profax2021.pdf

    Page 15, are the connectors for the machine. CT-40FA (angled) CT-40FS (straight)

    Page 13, are the connectors for your cables. LC-40 Pick male and female as needed

    I shop at weldingsupply.com, because they are the best price and a local store to me. If you're stuck on Tweco brand, let me know and I will try to provide numbers. I'm just more familiar with Lenco because I buy/own a lot of it
    Thank you, Stickman ! Lenco should be fine.
  • 05-02-2021
    Kelvin

    Re: Can I use #1 AWG welding cable for Dialarc HF ?

    You can get Chicom knockoff DINSE connectors pretty cheaply on ebay, FWIW. I bought some and they seem to work fine.
  • 05-01-2021
    Stick-man

    Re: Can I use #1 AWG welding cable for Dialarc HF ?

    Quote Originally Posted by Jonath108 View Post
    Does anyone know the exact tweeco adapter for a older Dialarc hf with 1/2” studs at the terminals. I would like quick connects on both leads where they connect to the welder.
    Thanks in advance
    J
    If you want quick connectors, look at the following. These are compatible with the popular 2-MPC Tweco connectors. I prefer Lenco brand for price and quality.

    https://profax-lenco.com/wp-content/...Profax2021.pdf

    Page 15, are the connectors for the machine. CT-40FA (angled) CT-40FS (straight)

    Page 13, are the connectors for your cables. LC-40 Pick male and female as needed

    I shop at weldingsupply.com, because they are the best price and a local store to me. If you're stuck on Tweco brand, let me know and I will try to provide numbers. I'm just more familiar with Lenco because I buy/own a lot of it
  • 05-01-2021
    Jonath108

    Re: Can I use #1 AWG welding cable for Dialarc HF ?

    Quote Originally Posted by Stick-man View Post
    Go to www.electronbeamtechnology.com

    I buy all my lead from them. Excellent quality, great prices.
    Does anyone know the exact tweeco adapter for a older Dialarc hf with 1/2” studs at the terminals. I would like quick connects on both leads where they connect to the welder.
    Thanks in advance
    J
  • 04-05-2021
    Jonath108

    Re: Can I use #1 AWG welding cable for Dialarc HF ?

    Thank you
  • 04-05-2021
    Jonath108

    Re: Can I use #1 AWG welding cable for Dialarc HF ?

    Quote Originally Posted by walker View Post
    Go feel it before you buy. I bought a hundred feet of 1/0 to extend my leads for a job. This was during the copper crisis ten years ago or so. I paid a premium for it because only Praxair had it in stock. It is the stiffest welding cable I have ever had. It never gets used unless I need the extra feet.
    Good advice, thanks.
  • 04-05-2021
    Stick-man

    Re: Can I use #1 AWG welding cable for Dialarc HF ?

    Go to www.electronbeamtechnology.com

    I buy all my lead from them. Excellent quality, great prices.
  • 04-05-2021
    walker

    Re: Can I use #1 AWG welding cable for Dialarc HF ?

    Go feel it before you buy. I bought a hundred feet of 1/0 to extend my leads for a job. This was during the copper crisis ten years ago or so. I paid a premium for it because only Praxair had it in stock. It is the stiffest welding cable I have ever had. It never gets used unless I need the extra feet.
  • 04-05-2021
    G-ManBart

    Re: Can I use #1 AWG welding cable for Dialarc HF ?

    Quote Originally Posted by Jonath108 View Post
    Are all welding cables about the same, or is their a brand that is superior ?
    Thanks
    There are some that are better than others. The quality of the jacket matters and the higher strand count the better...both lead to more flexible cables. I stay away from the imported cables....tends to be lower quality, and more importantly....it often stinks! Quality cable made in the U.S. can be quite flexible and actually smells nice.

    I've bought from this company many times...they're local to me, but sell on eBay and I think Amazon.

    This is for their red #1 cable, but they offer it in black and probably have a set with 20ft of black and 20ft or red if you look through their listings.

    https://www.ebay.com/itm/1-AWG-EXCEL...MAAOSwhOVXe9vP
  • 04-05-2021
    Jonath108

    Re: Can I use #1 AWG welding cable for Dialarc HF ?

    Are all welding cables about the same, or is their a brand that is superior ?
    Thanks
  • 04-05-2021
    Kelvin

    Re: Can I use #1 AWG welding cable for Dialarc HF ?

    Upsell!
  • 04-05-2021
    Jonath108

    Re: Can I use #1 AWG welding cable for Dialarc HF ?

    Quote Originally Posted by Oldendum View Post
    For your use, #2 should be more than adequate. If you are concerned, use a #1 work lead and a #2 stinger lead.

    I just had to move a big bundle of long 2/0 leads just a few feet. OMG heavy.
    When I called my LWS, they said #1, and both leads should be the same , as in #1 leads.
  • 04-05-2021
    Oldendum

    Re: Can I use #1 AWG welding cable for Dialarc HF ?

    For your use, #2 should be more than adequate. If you are concerned, use a #1 work lead and a #2 stinger lead.

    I just had to move a big bundle of long 2/0 leads just a few feet. OMG heavy.
  • 04-05-2021
    walker

    Re: Can I use #1 AWG welding cable for Dialarc HF ?

    Number 1 is perfect for that machine. It probably has something like #4 on it from the factory.
  • 04-05-2021
    Louie1961

    Re: Can I use #1 AWG welding cable for Dialarc HF ?

    I run 2 gauge on my syncrowave (which also goes up to 310 amps) and with short leads I have never had a problem.
  • 04-05-2021
    Kelvin

    Re: Can I use #1 AWG welding cable for Dialarc HF ?

    I suspect your welder would hit its duty cycle long before 20' of AWG #1 welding leads would.
  • 04-05-2021
    SweetMK

    Re: Can I use #1 AWG welding cable for Dialarc HF ?

    Quote Originally Posted by Jonath108 View Post
    Thanks,
    Looks like I should go for 1/0 just to be safe.
    You will use a 1/0 cable seven times, then toss it in the corner because it is too heavy.
  • 04-05-2021
    G-ManBart

    Re: Can I use #1 AWG welding cable for Dialarc HF ?

    Quote Originally Posted by Jonath108 View Post
    Thanks,
    Looks like I should go for 1/0 just to be safe.
    Why? 1/0 is good for up to 60% duty cycle at 350A as long as the leads are combined 50ft or less.....way more than what you're talking about. #1 is good for 60% at 300A so there is really no way you'd have an issue at 200A or lower. #1 is probably close to 100% at 200A with 50ft or less combined leads...and nobody can stick weld 100%.
  • 04-05-2021
    Jonath108

    Re: Can I use #1 AWG welding cable for Dialarc HF ?

    Quote Originally Posted by John T View Post
    Thanks,
    Looks like I should go for 1/0 just to be safe.
This thread has more than 25 replies. Click here to review the whole thread.