    Champion 10000 won't shutoff

    Welder works as it should. Kohler ch20 engine starts, runs , idles up and down but wont shut off with ignition switch. When switched to off position it goes to high idle!
    ESAB250w/spool gun attach
    MillerBobcat 225G
    MIllerEconotig 150
    MillerSynchrowave 350
    LincolnLn25
    Miller Xtreme 12S
    HobartMegaArc 300D
    MillerTrailblazer 44G
    2004FL70 14'mechanics body14k crane 70cfm compr

  2. #2
    Join Date
    Jan 2004
    Location
    Brethren, Mi
    Posts
    8,961
    Post Thanks / Like

    Re: Champion 10000 won't shutoff

    It may be the switch, look at drawing if you have one but I think it shorts it out. I had one on a briggs linc do that a while back.

  3. Likes Freebirdwelds, 12V71, 52 Ford liked this post
  4. #3
    Join Date
    May 2021
    Location
    Landrum, SC
    Posts
    1,361
    Post Thanks / Like

    Re: Champion 10000 won't shutoff

    Quote Originally Posted by Sberry View Post
    It may be the switch, look at drawing if you have one but I think it shorts it out. I had one on a briggs linc do that a while back.
    Got to start looking somewhere, this sounds as a good a place as any.
    Lincoln 330MPX
    Lincoln Power Mig 256
    Lincoln LN-25X Wire Feeder
    Lincoln AC/DC 225
    ¼ Ton of Torches OFC-A/OFG-A
    Air Carbon Arc Gouging
    CAC-A
    Lincoln Tomahawk 1000
    Ingersoll Rand T-30-14hp-25cfm
    Instagram: #Freebird Welds

  5. Likes 52 Ford liked this post
  6. #4
    Join Date
    Dec 2020
    Location
    Virginia, USA
    Posts
    11,003
    Post Thanks / Like

    Re: Champion 10000 won't shutoff

    Quote Originally Posted by trweld View Post
    Welder works as it should. Kohler ch20 engine starts, runs , idles up and down but wont shut off with ignition switch. When switched to off position it goes to high idle!
    Is high idle integrated into the off switch?

    Sounds like you have a multiposition rotary switch or toggle switch. Pop the switch out open it up, douse it in CircuitSafe, LectraMotive, or some other electronics cleaner that has a cool name (the cool name is important). Isopropyl alcohol would work, too. The idea being to wash away any contamination and to displace any water that may have made it into the switch.

    Could be as simple as that.

    Sent from my Lincoln Buzzbox using Tapatalk
    Sent via smoke signals using my Lincoln buzzbox

  7. Likes Freebirdwelds liked this post
  8. #5
    Join Date
    May 2014
    Location
    Central Wa. state
    Posts
    8,196
    Post Thanks / Like

    Re: Champion 10000 won't shutoff

    Quote Originally Posted by 52 Ford View Post
    Is high idle integrated into the off switch?

    Sounds like you have a multiposition rotary switch or toggle switch. Pop the switch out open it up, douse it in CircuitSafe, LectraMotive, or some other electronics cleaner that has a cool name (the cool name is important). Isopropyl alcohol would work, too. The idea being to wash away any contamination and to displace any water that may have made it into the switch.

    Could be as simple as that.

    Sent from my Lincoln Buzzbox using Tapatalk
    It goes to high idle because the 12 volts have been shut off... Ergo no power to the idle solenoid, the ignition switch probably also incorporates a magneto ground thats not working, I could be wrong but it's worth checking out.

  9. Likes Freebirdwelds, 52 Ford, whtbaron, CAVEMANN liked this post
  10. #6
    Join Date
    Dec 2020
    Location
    Virginia, USA
    Posts
    11,003
    Post Thanks / Like

    Re: Champion 10000 won't shutoff

    Quote Originally Posted by 12V71 View Post
    It goes to high idle because the 12 volts have been shut off... Ergo no power to the idle solenoid, the ignition switch probably also incorporates a magneto ground thats not working, I could be wrong but it's worth checking out.
    Sounds right to me.

    Kinda hard to diagnose something over the interwebs with out a lot of detail.

  11. #7
    Join Date
    May 2014
    Location
    Central Wa. state
    Posts
    8,196
    Post Thanks / Like

    Re: Champion 10000 won't shutoff

    Quote Originally Posted by 52 Ford View Post
    Sounds right to me.

    Kinda hard to diagnose something over the interwebs with out a lot of detail.
    Yup, bizzactly.

  12. Likes 52 Ford liked this post
  13. #8
    Join Date
    Feb 2019
    Location
    Snyder TX
    Posts
    643
    Post Thanks / Like

    Re: Champion 10000 won't shutoff

    If it is a Kohler check the solenoid on the carb bowl. I'll bet it is stuck open.

  14. Likes 52 Ford liked this post
  15. #9
    Join Date
    Mar 2018
    Location
    Clovis California
    Posts
    9,896
    Post Thanks / Like

    Re: Champion 10000 won't shutoff

    I never use switch.
    I turn off fuel so no fuel in carburetor.

    Dave

    Quote Originally Posted by trweld View Post
    Welder works as it should. Kohler ch20 engine starts, runs , idles up and down but wont shut off with ignition switch. When switched to off position it goes to high idle!

  16. Likes 52 Ford liked this post
  17. #10
    Join Date
    May 2008
    Location
    Orange, TX
    Posts
    18,081
    Post Thanks / Like

    Re: Champion 10000 won't shutoff

    Quote Originally Posted by cwby View Post
    If it is a Kohler check the solenoid on the carb bowl. I'll bet it is stuck open.

    What he said. The Kohler version cuts off fuel in the carb to shut the unit down rather than grounding out the ignition as is the case with the Onan and Robin models.
    MM200 w/Spoolmatic 1
    Syncrowave 180SD
    Bobcat 225G Plus - LP/NG
    MUTT Suitcase Wirefeeder
    WC-1S/Spoolmatic 1
    HF-251D-1
    PakMaster 100XL
    '68 Red Face Code #6633 project
    Star Jet 21-110

    Save Second Base!

  18. Likes 52 Ford, whtbaron liked this post
  19. #11
    Join Date
    May 2014
    Location
    Manitoba Canada
    Posts
    14,980
    Post Thanks / Like

    Re: Champion 10000 won't shutoff

    The welder won't shut off because you aren't done yet. Get back to work...
    250 amp Miller DialArc AC/DC Stick
    F-225 amp Forney AC Stick
    230 amp Sears AC Stick
    Lincoln 180C MIG
    Vevor MIG 200A
    Victor Medalist 350 O/A
    Vevor Cut 50 Plasma
    Les

  20. Likes 52 Ford, Freebirdwelds, mglsite liked this post
  21. #12
    Join Date
    Mar 2018
    Location
    Clovis California
    Posts
    9,896
    Post Thanks / Like

    Re: Champion 10000 won't shutoff

    I like 👍 👌

    Dave

    Quote Originally Posted by whtbaron View Post
    The welder won't shut off because you aren't done yet. Get back to work...

  22. #13
    Join Date
    Dec 2018
    Posts
    10,053
    Post Thanks / Like

    Re: Champion 10000 won't shutoff

    Kohler will go to high idle as part of the shutdown routine. It's perfectly normal.

    However............if it goes to high idle, and doesn't shut down..........it's the fuel shutoff solenoid.

    I've gone over this here before, and folks always try to say it's not right........until they see a properly working unit go to high idle as it shuts down. It's the way they're made, or the way the board is programmed.

  23. #14
    Join Date
    Dec 2018
    Posts
    10,053
    Post Thanks / Like

    Re: Champion 10000 won't shutoff

    Follow the video to the point he shuts the 250GXT down. Yet another repeat of the video for the non believers.

    The shutdown occurs at 11:29 in the video. If your machine goes to fast idle, but won't shut down.............idle solenoid
    Last edited by farmersammm; 07-09-2022 at 07:04 PM.

  24. Likes whtbaron liked this post
  25. #15
    Join Date
    Jun 2017
    Location
    AJO, ARIZONA
    Posts
    6,264
    Post Thanks / Like

    Re: Champion 10000 won't shutoff

    Quote Originally Posted by 52 Ford View Post
    Sounds right to me.

    Kinda hard to diagnose something over the interwebs with out a lot of detail.
    Yep, my daughter is constantly calling or texting me to diagnose something on their van, and it always starts with "what causes". Her husband almost got a a VERY painful lesson while charging the AC with one of those "NO GAUGE" charging hoses, he was holding the can and saw the bottom bulge, then the can got hot, he got the valve closed, but I hope they understand how close he was, turns out he overcharged it.THAT'S WHY I HATE THOSE CHEAPIE CHARGING KITS, hell nowadays you can get a cheap manifold set for what one of those kits cost.
    UNITWELD 175 AMP 3 IN1 DC
    MIDSTATES 300 AMP AC MACHINE
    LET'S GO BRANDON!"INFLATION-THAT'S THE PRICE WE PAY FOR THOSE GOVERNMENT BENEFITS EVERYBODY THOUGHT WERE FREE."RONALD REAGAN
    JEFF

  26. #16
    Join Date
    May 2014
    Location
    Central Wa. state
    Posts
    8,196
    Post Thanks / Like

    Re: Champion 10000 won't shutoff

    Quote Originally Posted by CAVEMANN View Post
    Yep, my daughter is constantly calling or texting me to diagnose something on their van, and it always starts with "what causes". Her husband almost got a a VERY painful lesson while charging the AC with one of those "NO GAUGE" charging hoses, he was holding the can and saw the bottom bulge, then the can got hot, he got the valve closed, but I hope they understand how close he was, turns out he overcharged it.THAT'S WHY I HATE THOSE CHEAPIE CHARGING KITS, hell nowadays you can get a cheap manifold set for what one of those kits cost.
    I've been charging trucks left and right for the last 3 weeks, if they just need a topoff I just recover what's in the system, inject new oil to make up for the oil my machine stole, program the amount of 134 they take and push a button. Perfect "freeze your toenails off" cooling every time. Tried topping off a Peterbilt using the pressure/temp method awhile back, it took 45 minutes to get it cold.
    Name:  20220705_130823.jpg
Views: 740
Size:  92.5 KB

  27. #17
    Join Date
    May 2014
    Location
    Manitoba Canada
    Posts
    14,980
    Post Thanks / Like

    Re: Champion 10000 won't shutoff

    The tractors seem to need a little puff every 3 yrs or so.... any more than that is usually an indication of a leak.
    250 amp Miller DialArc AC/DC Stick
    F-225 amp Forney AC Stick
    230 amp Sears AC Stick
    Lincoln 180C MIG
    Vevor MIG 200A
    Victor Medalist 350 O/A
    Vevor Cut 50 Plasma
    Les

+ Reply to Thread

Quick Reply Quick Reply

Register Now

Please enter the name by which you would like to log-in and be known on this site.

Please enter a password for your user account. Note that passwords are case-sensitive.

Please enter a valid email address for yourself.

A) Welding/Fabrication Shop
B) Plant/Production Line
C) Infrastructure/Construction/Repair or Maintenance/Field Work
D) Distributor of Welding Supplies or Gases
E) College/School/University
F) Work Out of Home

A) Corporate Executive/Management
B) Operations Management
C) Engineering Management
D) Educator/Student
E) Retired
F) Hobbyist

Log-in

Posting Permissions

  • You may post new threads
  • You may post replies
  • You may not post attachments
  • You may not edit your posts
  •  
Page generated in 1,713,296,328.34061 seconds with 21 queries