    Re: How to Properly Crimp 1/0 ultra flex cable ?

    Quote Originally Posted by smithdoor View Post
    It is stud size on most welders.
    The nut holds the copper connector you just solder to cable.

    Most studs use 1/2" brass .

    The low cost welders will almost any size as found out.
    After I retired and sold my business I purchased a small welder from Harbor Frieght it used monkey threads aka metric.

    Dave

    FYI if the monkey threads fail or nut runs away I plan to real American threads 1/2" NC like all American welders use.
    Thank you

  2. #27
    Join Date
    Jun 2017
    Location
    AJO, ARIZONA
    Posts
    6,264
    Post Thanks / Like

    Re: How to Properly Crimp 1/0 ultra flex cable ?

    Quote Originally Posted by Jonath108 View Post
    Thank you,
    I am able to pull the cable out with not much force. I am using long barrel 1/0-2/0 copper lugs. I do put double crimps as well.
    I do not have much room when I push the bare multi stranded wire into the lug. I am also getting grooves at the underside of the lug from the Temco hammer crimp tool. I am not sure if that is also a problem.
    I've had and used this type of crimper since 1985, mine works great, gives a tight crimp that can be shrunk wrap easily, I have used it in a vise or hydraulic press, it has always given good results
    UNITWELD 175 AMP 3 IN1 DC
    MIDSTATES 300 AMP AC MACHINE
    LET'S GO BRANDON!"INFLATION-THAT'S THE PRICE WE PAY FOR THOSE GOVERNMENT BENEFITS EVERYBODY THOUGHT WERE FREE."RONALD REAGAN
    JEFF

  3. #28
    Join Date
    May 2010
    Location
    Ct.
    Posts
    1,771
    Post Thanks / Like

    Re: How to Properly Crimp 1/0 ultra flex cable ?

    With the Deka crimper that I use ( which I
    think is the same thing) you need to whack
    it pretty good , several times , and the base
    needs to be setting on something solid.
    You can tell when the lug is crimped tightly by
    the sound and feel when you hit it.
    Miller a/c-d/c Thunderbolt XL
    Millermatic 180
    Purox O/A
    Smith Littletorch O/A
    Hobart Champion Elite

  4. #29
    Join Date
    May 2008
    Location
    Orange, TX
    Posts
    18,081
    Post Thanks / Like

    Re: How to Properly Crimp 1/0 ultra flex cable ?

    This is the cable terminal crimper I made several years ago to mimic those found on Miller machines. Works with my 20T press or big up-n-down wrench.
    Attached Images Attached Images      
    MM200 w/Spoolmatic 1
    Syncrowave 180SD
    Bobcat 225G Plus - LP/NG
    MUTT Suitcase Wirefeeder
    WC-1S/Spoolmatic 1
    HF-251D-1
    PakMaster 100XL
    '68 Red Face Code #6633 project
    Star Jet 21-110

    Save Second Base!

  5. Likes filetobeef, 12V71, Welder Dave, Zebidiah liked this post
  6. #30
    Join Date
    Oct 2014
    Posts
    2,135
    Post Thanks / Like

    Re: How to Properly Crimp 1/0 ultra flex cable ?

    The best crimps on these soft copper barrels is the crimper that looks like a big pair of bolt cutters (or hydraulic). Far superior crimp.

    Usually a bit too expensive to buy for occasional use though hence the reason for the hammer style ones being so popular.

    I have a really nice one for #10, #8, #6 and #4 lugs each die rotates 4 positions and they lock in position.
    They crush in 4 directions(dies form a square when closed)effectively reducing the I.D. all the way around evenly.

  7. #31
    Join Date
    Sep 2016
    Location
    Detroit, Michigan
    Posts
    1,534
    Post Thanks / Like

    Re: How to Properly Crimp 1/0 ultra flex cable ?

    Quote Originally Posted by jpump5 View Post
    With the Deka crimper that I use ( which I
    think is the same thing) you need to whack
    it pretty good , several times , and the base
    needs to be setting on something solid.
    You can tell when the lug is crimped tightly by
    the sound and feel when you hit it.
    Same here. I have a 4x4" piece of 1/2" thick steel to set the crimper on and put the whole thing on the concrete floor. I hold the wire in place and use a lighter hit to secure the wire, then get my hand out of the way and give it a couple of good smacks with a small sledge hammer and that always does the trick.
    Check out my bench vise website:
    http://mivise.com


    Miller Syncrowave 250DX
    Millermatic 350P with XR AlumaPro
    Miller Regency 200 with 22A feeder and Spoolmatic 3
    Hobart Champion Elite
    Everlast PowerTig 210EXT

  8. Likes 12V71 liked this post
+ Reply to Thread

Quick Reply Quick Reply

Register Now

Please enter the name by which you would like to log-in and be known on this site.

Please enter a password for your user account. Note that passwords are case-sensitive.

Please enter a valid email address for yourself.

A) Welding/Fabrication Shop
B) Plant/Production Line
C) Infrastructure/Construction/Repair or Maintenance/Field Work
D) Distributor of Welding Supplies or Gases
E) College/School/University
F) Work Out of Home

A) Corporate Executive/Management
B) Operations Management
C) Engineering Management
D) Educator/Student
E) Retired
F) Hobbyist

Log-in

Posting Permissions

  • You may post new threads
  • You may post replies
  • You may not post attachments
  • You may not edit your posts
  •  
Page generated in 1,713,269,709.67651 seconds with 21 queries